40um - 260um Blood Tubular Filter Diameter D16.2xh52.3mm for Transfusion Set, Sterilization & Non-Sterilization

Product Details
Customization: Available
Sterilization: Non Sterilization
Feature: Disposable
Still deciding? Get samples of US$ 0/Piece
Request Sample
Manufacturer/Factory
Gold Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
6000000 RMB
Plant Area
1001~2000 square meters
  • 40um - 260um Blood Tubular Filter Diameter D16.2xh52.3mm for Transfusion Set, Sterilization & Non-Sterilization
  • 40um - 260um Blood Tubular Filter Diameter D16.2xh52.3mm for Transfusion Set, Sterilization & Non-Sterilization
  • 40um - 260um Blood Tubular Filter Diameter D16.2xh52.3mm for Transfusion Set, Sterilization & Non-Sterilization
  • 40um - 260um Blood Tubular Filter Diameter D16.2xh52.3mm for Transfusion Set, Sterilization & Non-Sterilization
  • 40um - 260um Blood Tubular Filter Diameter D16.2xh52.3mm for Transfusion Set, Sterilization & Non-Sterilization
  • 40um - 260um Blood Tubular Filter Diameter D16.2xh52.3mm for Transfusion Set, Sterilization & Non-Sterilization
Find Similar Products

Basic Info.

Model NO.
40 70 100 150 170 200 263 micron tubular filter
Application
Clinical
Material
Plastic
Certification
FDA, Reach
Mesh Material
100% PA6 Mesh, Polyester Mesh
Micron Rating
15um-300um
Mesh Processing
Laser Cut, Punching
Support Rim
PP, PA6, ABS
Processing
Over Moulding
Size
D16.2xh52.3mm, Customized
Packing
Polybag, Carton
Fit for
Infusion IV Drip Chamber
Products Types
Filter Mesh in Disc, Moulded Filter
OEM/ODM
Acceptable
Transport Package
Polybag, Carton
Specification
D16.2xH52.3mm, Customize size
Trademark
Share Filters
Origin
China
HS Code
84219910
Production Capacity
5000PCS/ Day

Product Description

The blood transfusion tubular filter is an essential component in the blood transfusion set, playing a pivotal role in enhancing the safety and efficacy of the transfusion process. Comprising a filter mesh endowed with pore sizes ranging from 40 to 260 microns in diameter, the blood tranfusion filter serves as a meticulous gatekeeper during the journey of blood from donor to recipient.

 

Share Filters' blood filter consists of a polyester or nylon filter mesh held in polymer by insert injection moulding, allowing for a more robust part giving more reliability and longevity in its usage. Micron rating available in 40μm, 150μm, 170μm, 200μm, 260μm, and other specified microns. This injection moulding processing can take in many forms.

 
Property of Share Filters' Blood Transfusion Filter

  • Carefully selected high quality medical grade materials
  • Wide range of filtration micron rating of filter mesh available
  • All the processings are dealing in-house
  • Cost Effective: many sizes availabe, save the cost of tooling
  • Efficiency of filtration 98%
  • Pyrogenicity <0.25 EU/ml
  • Maximum operating temperature 50°C
  • Low extractable levels and wide drug compatibility

  • Latex-free, PVC-free, and free of animal-origin substances

40um - 260um Blood Tubular Filter Diameter D16.2xh52.3mm for Transfusion Set, Sterilization &amp; Non-Sterilization

 


Technical Data
Product name: Blood tubular filter Cage material: PP PA PS ABS, others
Application: For transfusion drip chamber Filter medium: Nylon mesh, polyester mesh
Total length: 52.3mm, custom Micron rating: 5μm 10μm 20μm 30μm 40μm 70μm 100μm, 200μm, ect
External ring diameter: 16.2mm, custom Color: Clear, white, cream, other custom color
Internal ring diameter: 11.95mm, custom Package: Plastic bag, master carton

Customization

We can also use other colors,shapes, or materials instead of our available versions on request.
If the desired dimensions of the tubular filters are not included in our range, we can customize according to your specifications.


 Product Pictures
40um - 260um Blood Tubular Filter Diameter D16.2xh52.3mm for Transfusion Set, Sterilization &amp; Non-Sterilization
40um - 260um Blood Tubular Filter Diameter D16.2xh52.3mm for Transfusion Set, Sterilization &amp; Non-Sterilization
 
40um - 260um Blood Tubular Filter Diameter D16.2xh52.3mm for Transfusion Set, Sterilization &amp; Non-Sterilization
40um - 260um Blood Tubular Filter Diameter D16.2xh52.3mm for Transfusion Set, Sterilization &amp; Non-Sterilization
40um - 260um Blood Tubular Filter Diameter D16.2xh52.3mm for Transfusion Set, Sterilization &amp; Non-Sterilization

 

Nylon(PA6) Filter Mesh Datasheet
 

Fabric Number Mesh Count Thread Diameter Mesh Opening Open Area Mesh Thickness Weight
  n/cm n/inch μm μm % μm g/m2
PA 533/41 12 30 300 533 41 585 234
PA 414/34 14 35 300 414 34 595 273
PA 425/46 16 40 200 425 46 370 139
PA 375/36 16 40 250 375 36 485 217
PA 350/49 20 50 150 350 49 375 98
PA 300/36 20 50 200 300 36 385 173
PA 267/41 24 60 150 267 41 285 117
PA 237/44 28 70 120 237 44 215 87
PA 213/41 30 76 120 213 41 225 94
PA 213/46 32 80 100 213 46 165 69
PA 178/41 36 90 100 178 41 178 78
PA 150/36 40 100 100 150 36 190 87
PA 152/43 43 110 80 152 42 135 60
PA 130/38 48 120 80 130 38 145 62
PA 120/44 56 140 60 120 44 85 44
PA 110/42 59 150 60 110 41 98 46
PA 100/37 64 160 60 100 38 105 50
PA 90/41 72 180 50 90 41 82 39
PA 75/36 80 200 50 75 36 90 43
PA 60/36 100 250 42 60 34 65 35
PA 42/25 120 305 42 42 24 75 42
PA 44/27 120 305 38 44 29 72 35
PA 42/25 120 305 38 42 25 67 35
PA 45/29 120 305 35 45 33 60 28
PA 55/42 120 305 30 55 40 52 20
PA 40/26 130 330 38 40 25 74 36
PA 42/30 130 330 35 42 29 62 30
PA 47/37 130 330 30 47 37 55 22
PA 32/20 140 355 38 32 21 68 36
PA 37/26 140 355 35 37 26 65 33
PA 38/28 140 355 30 38 33 53 25
PA 31/21 150 380 38 31 18 68 40
PA 35/27 150 380 30 35 29 57 26
PA 34/26 150 380 30 34 26 50 26
PA 30/25 165 420 30 30 25 59 28
PA 30/19 145 368 38 30 19 64 40
PA 25/21 180 460 30 25 21 60 31
PA 25/15 165 420 38 25 15 75 42
PA 20/16 200 508 30 20 16 65 34
PA 10/4.3 208 530 38 10 4.3 77 53
PA 8/3 220 560 38 8 3 78 56
PA 6/1.7 228 580 38 6 1.7 80 59
PA 3/1 236 600 38 3 1 85 61

This just a part of specifications which common used.

 
40um - 260um Blood Tubular Filter Diameter D16.2xh52.3mm for Transfusion Set, Sterilization &amp; Non-Sterilization

Mesh count (n/cm), (n/in)

The mesh count stands for the number of openings per inch.

 

Mesh opening (μm)

The mesh opening w is the distance between two adjacent warp or weft thread.

 

Thread diameter (μm)

The thread diameter is measured on the thread before weaving.

 

Open area (%)

The percentage of the open are is the sum of all mesh openings as percentage of the total fabric area



Other Mesh Filters for Medical and Healthcare 

40um - 260um Blood Tubular Filter Diameter D16.2xh52.3mm for Transfusion Set, Sterilization &amp; Non-Sterilization



Example of Application

40um - 260um Blood Tubular Filter Diameter D16.2xh52.3mm for Transfusion Set, Sterilization &amp; Non-Sterilization


What Share Filters Do?

40um - 260um Blood Tubular Filter Diameter D16.2xh52.3mm for Transfusion Set, Sterilization &amp; Non-Sterilization

Factory Capabilities40um - 260um Blood Tubular Filter Diameter D16.2xh52.3mm for Transfusion Set, Sterilization &amp; Non-Sterilization
 


Photos of Factory
40um - 260um Blood Tubular Filter Diameter D16.2xh52.3mm for Transfusion Set, Sterilization &amp; Non-Sterilization
 

Contact Us

 

Share Filters provides some information for filter mesh possible applications, but there are too many functions for comprehensive descriptions of possible uses. Therefore, when considering a potential application in your particular industry, please consider contacting us who will work with engineers and product designers in choosing the right material and processing for your specific projects.


Please connect with us now so we can learn more about your application and design specifications!



FAQ

Are You Factory or Trade Company ?
We're factory, and manufacture our products in-house.

Where Is Your factory Located? How Can I Get There?
We are in Tiantai city, Zhejiang province China. By train, one hour away from Hangzhou and two hours away from Shanghai.


Which Port You Ship?
Ningbo port.

Can I Get Free Samples ?
We are pleased to provide you with free samples for testing, just the freight will be at your account.


What's Your Payment Term ?
T/T, LC, PayPal, and others.

What's the Lead Time of the Order?
The production lead time is dependent on the quantity. It takes 5 to 20 working days for us to complete mass production after receive the payment.


What About Your Quality Control?
By visual inspection, optical or pressure sensitive equipment and automated 3D image-inspection equipment, our production operators conduct self-inspections at every stage of the process, from the raw material to finshed products. Additionally, we have spot inspections and final inspections carried out by our QC team.


Why Choose You ?
One of our core competencies is our excellent processing capabilities, convert the woven filter mesh to mesh ribbons, discs, shapes, tubes, bags, plastic moulded filters, with advanced equipments and professional technical team for more than 20 years. We're the few supplier who have experience with synthetic filter meshes and are able to use them with plastic moulding in good conditions.


How To Delivery the Order?
Small batch is sent by UPS, Fedex, TNT, DHL, EMS, ect, high volume will be shipped by sea and air.


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
People who viewed this also viewed