330 Mesh 40 Um Laboratory Disposable Cell Strainer, PP/Nylon, Separating Cells From Solution or Tissue Sample, Compatible with 50 Ml Centrifuge Tubes

Product Details
Customization: Available
Material: Molded Polypropylene Frame and Nylon Mesh Filter
Application: Industry, Medicine
Still deciding? Get samples of US$ 1/Square Meter
Request Sample
Manufacturer/Factory
Gold Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
6000000 RMB
Plant Area
1001~2000 square meters
  • 330 Mesh 40 Um Laboratory Disposable Cell Strainer, PP/Nylon, Separating Cells From Solution or Tissue Sample, Compatible with 50 Ml Centrifuge Tubes
  • 330 Mesh 40 Um Laboratory Disposable Cell Strainer, PP/Nylon, Separating Cells From Solution or Tissue Sample, Compatible with 50 Ml Centrifuge Tubes
  • 330 Mesh 40 Um Laboratory Disposable Cell Strainer, PP/Nylon, Separating Cells From Solution or Tissue Sample, Compatible with 50 Ml Centrifuge Tubes
  • 330 Mesh 40 Um Laboratory Disposable Cell Strainer, PP/Nylon, Separating Cells From Solution or Tissue Sample, Compatible with 50 Ml Centrifuge Tubes
Find Similar Products
  • Overview
  • Product Parameters
  • Product Description
  • Filter Material Selection
  • Technical Data Sheet
  • Plastic material selection
  • Product Gallery
  • FAQ
Overview

Basic Info.

Model NO.
SG-CS-02
Filter Connector
Flat Connector
Filtration Grade
Medium Filter
Activated Carbon Filter Type
Compact
Pore Size
40um
Frame Color
Purle
Fit for
50ml Conical Tubes
Features
Bulk Packaged, Easy Handling, Colored by Mesh Size
Transport Package
PE Bag and Standard Export Carton by Couier by Sea
Specification
3.57*1.45CM
Trademark
SHARE FILTERS
Origin
Zhejiang, China
HS Code
84219910
Production Capacity
50, 000 PCS/ Week

Product Description

Product Parameters

Product Name 40 UM Cell Strainers, 330 Nylon Mesh, PP Frame, Fitting For Biologix 50ml Centrifuge Tubes
Manufacturer Taizhou Share Filters Co. Ltd.
Brand SHARE FILTERS
Material Made of sturdy polypropylene and strong nylon mesh
Color Purple, color coded by pore size for convenience
Size 3.57*1.45cm or customized
Fit for Most brands of 50mL centrifuge tubes
Pore Size 40um. 1um to 500um are available upon request
Advantages No heat source (no endotoxin)
Sterilization, individually packaged in aseptic conditions
Polypropylene frame with protrusions on the sides for easy handling
Nylon mesh sizes: 1μm to 500μm, gererally 40μm, 70μm, 100μm, meeting the requirements for filtering and separating different cells
Different specifications correspond to different colors, easy to distinguish
Unique handle design for convenient retrieval
Compatible with 50mL centrifuge tubes, used for laboratory cell culture, flow cytometer cell samples, impurity filtration, cell dispersion, sampling, etc.
Applications Obtaining a real single cell suspension after digestion of mammary tissue and organoids
Preparation of a single cell suspension of blood cells from bone marrow, pancreas, thymus, lymph nodes and others
Dissociation of cells from other primary tissue
Preparation of real single cell suspension for flow cytometry
Faster and easier alternative to gauze filtration
Sieving of complex and viscous liquids (in combination with Connector Ring & Syringe for vacuum)
Short time incubation of cells / cytokine
Package Individual single packaged, 100pcs/carton

Product Description

In cell biology and research, separating cell populations from debris or aggregates is a critical step. Fine mesh cell strainers play a key role in ensuring the isolation of single cell suspensions for accurate analysis.

SHARE offers our insert molded plastic cell strainer for a wide range of laboratory applications where filtration and purification of liquids is required. Its unique design features improved venting to prevent clogging for intelligent sample preparation. Our Cell Strainers are stackable to allow direct filtration with different mesh sizes and can also be inverted to recover the screened material. It can be combined with a funnel for large sample volumes. It fits all major brands of 50 mL centrifuge conical tubes.

330 Mesh 40 Um Laboratory Disposable Cell Strainer, PP/Nylon, Separating Cells From Solution or Tissue Sample, Compatible with 50 Ml Centrifuge Tubes
Pore Size Item Size
40um 40um Cell Strainers, Sterile, Nylon Mesh, PP Frame, Purple, Individual Packed, 100 Pieces/Case 100 pieces
70um 70um Cell Strainers, Sterile, Nylon Mesh, PP Frame, Orange, Individual Packed, 100 Pieces/Case 100 pieces
100um 100um Cell Strainers, Sterile, Nylon Mesh, PP Frame, Green, Individual Packed, 100 Pieces/Case 100 pieces
 

 

Filter Material Selection

Each batch of SHARE's filter meshes undergoes a meticulous process involving at least twelve distinct steps, ensuring the ultimate production of high-quality filtering products.

330 Mesh 40 Um Laboratory Disposable Cell Strainer, PP/Nylon, Separating Cells From Solution or Tissue Sample, Compatible with 50 Ml Centrifuge Tubes
The twelve steps of SHARE filter mesh production procedure are: 

Yarn→Raw yarn inspection→Warping arranging→Drawing in heddle→Drawing in reed→Weaving→Initial survey→Washing→Heat setting treatment→Physical properties inspection→Products inspection→Product→(Prefabrated filter and screens if needed)→(Molded plastic filters if needed)

Technical Data Sheet

The below table will provide information on the mesh opening, open area percentage, mesh count, and thread diameter on all of our various pore sizes of nylon mesh offered.

Precision Nylon Filter Mesh Data Sheet
Fabric Number Mesh  count  Thread Diameter Mesh  Opening Open  Area Fabric Thickness Weight 
No. cm mesh/inch micron micron % micron g/m2
JPP5 5 12 500 1500 56 850 271
JPP6 6 16 400 1267 58 780 208
JPP7 7 18 350 1079 57 675 186
JPP8 8 20 350 900 52 685 212
JPP9 9 24 250 860 60 455 145
JPP10 10 25 300 700 49 576 195
JPP12 12 30 250 583 49 470 162
JPP12 12 35 300 533 41 585 234
JPP14 14 40 300 414 34 595 273
JPP16 16 40 200 425 46 370 139
JPP16 16 50 250 375 36 485 217
JPP20 20 50 150 350 49 375 98
JPP20 20 50 200 300 36 385 173
JPP24 24 60 150 267 41 285 117
JPP28 28 70 120 237 44 215 87
JPP30 30 76 120 213 41 225 94
JPP32 32 80 100 213 46 165 69
JPP36 36 90 100 178 41 178 78
JPP40 40 100 100 150 36 190 87
JPP43 43 110 80 152 43 135 60
JPP48 48 120 80 130 38 145 62
JPP56 56 140 60 120 44 85 44
JPP59 59 150 60 110 42 98 46
JPP64 64 160 60 100 37 105 50
JPP72 72 180 50 90 41 82 39
JPP80 80 200 50 75 36 90 43
JPP100 100 250 40 60 36 65 35
JPP120 120 305 40 43 25 70 29
JPP130 130 330 40 37 23 75 31
JPP140 140 355 30 38 33.7 60 33
JPP150 150 381 30 34 30.25 52 26
JPP165 165 420 30 28 20.7 51 29
JPP180 180 460 30 25 19.5 58 31
JPP200 200 510 30 16 10.2 58 35
The data are compiled to the best of our knowledge. Subject to change without notice. 

Mesh Count: Number of openings per inch or centimeter
Weave 
Type: Plain Weave (PW) or Twill Weave (TW)
Thread Diameter: The diameter of each thread before weaving
Mesh 
Thickness: The average thickness of the woven mesh
Mesh 
Opening: The distance between adjacent threads

Mesh Opening =25400÷Mesh Count(per inch)−Wire Diameter
Mesh Opening =10000÷Mesh Count(per cm)−Wire Diameter

Open Area: The ratio (%) of the open area to the thread area within a woven mesh
Open Area %=(Opening Size)
2÷(Opening Size+Wire Diameter)2×100

  
330 Mesh 40 Um Laboratory Disposable Cell Strainer, PP/Nylon, Separating Cells From Solution or Tissue Sample, Compatible with 50 Ml Centrifuge Tubes
330 Mesh 40 Um Laboratory Disposable Cell Strainer, PP/Nylon, Separating Cells From Solution or Tissue Sample, Compatible with 50 Ml Centrifuge Tubes
330 Mesh 40 Um Laboratory Disposable Cell Strainer, PP/Nylon, Separating Cells From Solution or Tissue Sample, Compatible with 50 Ml Centrifuge Tubes
 

Plastic material selection

Material property is an important know-how to injection molding. It is highly related with molding quality, finish and cost. Our team devote this knowledge and experience to the molding products of our customers. From various thermoplastic (PA, PP, PC, POM, PET, ABS and Peek) to thermosetting (PE, Epoxy and Silicon) even combined plastic materials (such as glass fiber), we put material property as a must-evaluation when design tooling, so we would also help to suggest equivalent materials for quality improvement or cost reduction. 

Artificial or Synthetic Fiber Chemical Resistance Comparison
Fiber Type Continuous Working Temp. Max. Working Temp. Filtration Characteristic Abrasion Resistance Hydrolysis Resistance Acid Resistance Alkalis Resistance Oxidation Resistance
PVC 75ºC 80ºC Good Excellent Excellent Excellent Excellent Good
PP 90ºC 100ºC Good Good Excellent Excellent Excellent Poor
PA 110ºC 115ºC Moderate Excellent Poor Moderate Good Moderate
PAN Copolymer 120ºC` 130ºC Good Good Good Moderate Moderate Good
PET 135ºC 150ºC Excellent Excellent Poor Moderate Poor Good
m-Aramide 180ºC 220ºC Excellent Excellent Moderate Moderate Moderate Good
PPS 190ºC 200ºC Excellent Good Excellent Excellent Excellent Moderate
Polyimide 240ºC 280ºC Excellent Moderate Good Good Moderate Excellent
Polyertrafluoroethylene 250ºC 280ºC Moderate Good Excellent Excellent Excellent Excellent
Fiberglass 250ºC 280ºC Moderate Moderate Excellent Poor Moderate Excellent

Product Gallery

SHARE has the ability to engineer woven mesh fabrics into finished or partly finished products by insert molding or over molding. With its industrial lines and long-standing experience, we provide fabrics cut to size, lot-to-lot consistency and high quality custom fabricated components, in almost any requested shapes.

SHARE application speciallists with decades of years experiences will help you select the best filter for your application.
330 Mesh 40 Um Laboratory Disposable Cell Strainer, PP/Nylon, Separating Cells From Solution or Tissue Sample, Compatible with 50 Ml Centrifuge Tubes
330 Mesh 40 Um Laboratory Disposable Cell Strainer, PP/Nylon, Separating Cells From Solution or Tissue Sample, Compatible with 50 Ml Centrifuge Tubes
330 Mesh 40 Um Laboratory Disposable Cell Strainer, PP/Nylon, Separating Cells From Solution or Tissue Sample, Compatible with 50 Ml Centrifuge Tubes
330 Mesh 40 Um Laboratory Disposable Cell Strainer, PP/Nylon, Separating Cells From Solution or Tissue Sample, Compatible with 50 Ml Centrifuge Tubes
330 Mesh 40 Um Laboratory Disposable Cell Strainer, PP/Nylon, Separating Cells From Solution or Tissue Sample, Compatible with 50 Ml Centrifuge Tubes
330 Mesh 40 Um Laboratory Disposable Cell Strainer, PP/Nylon, Separating Cells From Solution or Tissue Sample, Compatible with 50 Ml Centrifuge Tubes

FAQ

1. Who are we?
Taizhou Share Filters Co., Ltd is a China-based factory established in 1983.
We specialize in filter media with rating from 3um to 2500um (woven filters), converting meshes filters into various sizes and shapes, and molding mesh with plastic to create different types of plastic filters.

2. How long does a quotation take?
In most cases, we respond within one working day. If something in RFQ need be confirmed, we will promptly notify you soon.

3. How quickly can I get my order finished?
The production lead time is dependent on the quantity. Typically, it takes 5 to 15 working days for us to complete mass production once you have placed the order.

4. What about your quality control?
Our production operators conduct self-inspections at every stage of the process. Additionally, we have spot inspections and final inspections carried out by our Quality Control (QC) team.


5. What kind of payment terms do you accept?
T/T and LC and more.

6. What's your largest advantage?

One of our core competencies is the production of high precision injection molded plastic filters with professional technical team and quality guarantee and management for more than 30 years.

7. Can plastic molded filter specifications be customized?
Absolutely, at SHARE, the materials, dimensions, shape, construction method, mesh size, and applications of the filters are all fully customizable to meet your specific requirements.


8. Do you need drawings for production?
If you have drawing (2D, 3D both available. 2D like PDF, CAD, JPG etc. 3D like STP, IGS, STL, SAT, PRT, IPT etc.) it'll be helpful for us to proceed with the production.
However, if you don't have any drawing, don't worry. SHARE can work with you to create a drawing based on a description or image of the filters you have in mind. We can get started without any drawings initially.


9. How do I know my design will be kept confidential?
At SHARE, we take confidentiality seriously. We are willing to sign and adhere to any non-disclosure or confidentiality agreement with our customers. Moreover, we have strict confidentiality policies within our factory, ensuring that no proprietary information is ever disclosed to any third party.


10. What are the common weaving types for plastic molded filters?
The most common weaving type is plain weave mesh, but we also utilize other options like twill weave mesh. Plain weave mesh is popular and affordable.

11. What situations can be anticipated in which plastic molded filters should be selected?
Plastic molding is better for mounting in the case of sandwiching. This is because it can be made without gaps in the shape of the mounting partner.

Plastic molding is preferable for mounting purposes, especially when sandwiching is required. This method allows us to create filters without any gaps to perfectly fit the mounting partner's shape.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
People who viewed this also viewed